← Back to Documentation Home
CCPP SciDoc v8.0.0  v8.0.0
Common Community Physics Package Developed at DTC
 
Loading...
Searching...
No Matches
module_radlw_kgb01 Module Reference

This module sets up absorption coefficients for band 01: 10-350 cm-1 (low - h2o; high - h2o) More...

Variables

integer, public msa01
 msa01=65
 
integer, public msb01
 msb01=235
 
integer, public msf01
 msf01=10
 
integer, public mfr01
 mfr01=4
 
integer, public mmn01
 mmn01=19
 
real(kind=kind_phys), dimension(ng01, msa01), public absa
 the array absa(NG01,65) = ka(NG01,5,13) contains absorption coefs at the NG01=10 chosen g-values for a range of pressure levels>~100mb and temperatures. the first index in the array, jt, which runs from 1 to 5, corresponds to different temperatures. more specifically, jt = 1-5 means that the data are for the corresponding temperature of tref-30, tref-15, tref, tref+15, and tref+30, respectively. the second index, jp, runs from 1 to 13 and refers to the corresponding pressure level in pref (e.g. jp = 1 is for a pressure of 1053.63 mb). the third index, ig, goes from 1 to NG01=10, and tells us which g-interval the absorption coefficients are for.
 
real(kind=kind_phys), dimension(ng01, msb01), public absb
 the array absb(NG01,235) = kb(NG01,5,13:59) contains absorption coefs at the NG01=10 chosen g-values for a range of pressure levels < ~100mb and temperatures. the first index in the array, jt, which runs from 1 to 5, corresponds to different temperatures. more specifically, jt = 1-5 means that the data are for the corresponding temperature of tref-30, tref-15, tref, tref+15, and tref+30, respectively. the second index, jp, runs from 13 to 59 and refers to the jpth reference pressure level (see taumol.f for the value of these pressure levels in mb). the third index, ig, goes from 1 to NG01=10, and tells us which g-interval the absorption coefficients are for.
 
real(kind=kind_phys), dimension(ng01, msf01), public selfref
 the array selfref contains the coefficient of the water vapor self-continuum (including the energy term). the first index refers to temperature in 7.2 degree increments. for instance, jt = 1 refers to a temperature of 245.6, jt = 2 refers to 252.8, etc. the second index runs over the g-channel (1 to NG01=10).
 
real(kind=kind_phys), dimension(ng01, mfr01), public forref
 the array forref contains the coefficient of the water vapor foreign-continuum (including the energy term). the first index refers to reference temperature (296,260,224,260) and pressure (970,475,219,3 mbar) levels. The second index runs over the g-channel (1 to NG01=10).
 
real(kind=kind_phys), dimension(ng01), public fracrefa
 planck fraction mapping level: p = 212.7250 mbar, t = 223.06 k
 
real(kind=kind_phys), dimension(ng01), public fracrefb
 planck fraction mapping level: p = 212.7250 mbar, t = 223.06 k these planck fractions were calculated using lower atmosphere parameters.
 
real(kind=kind_phys), dimension(ng01, mmn01), public ka_mn2
 
real(kind=kind_phys), dimension(ng01, mmn01), public kb_mn2
 

Detailed Description

This module sets up absorption coefficients for band 01: 10-350 cm-1 (low - h2o; high - h2o)

Variable Documentation

◆ absa

real (kind=kind_phys), dimension(ng01,msa01), public module_radlw_kgb01::absa

the array absa(NG01,65) = ka(NG01,5,13) contains absorption coefs at the NG01=10 chosen g-values for a range of pressure levels>~100mb and temperatures. the first index in the array, jt, which runs from 1 to 5, corresponds to different temperatures. more specifically, jt = 1-5 means that the data are for the corresponding temperature of tref-30, tref-15, tref, tref+15, and tref+30, respectively. the second index, jp, runs from 1 to 13 and refers to the corresponding pressure level in pref (e.g. jp = 1 is for a pressure of 1053.63 mb). the third index, ig, goes from 1 to NG01=10, and tells us which g-interval the absorption coefficients are for.

Definition at line 1639 of file radlw_datatb.f.

◆ absb

real (kind=kind_phys), dimension(ng01,msb01), public module_radlw_kgb01::absb

the array absb(NG01,235) = kb(NG01,5,13:59) contains absorption coefs at the NG01=10 chosen g-values for a range of pressure levels < ~100mb and temperatures. the first index in the array, jt, which runs from 1 to 5, corresponds to different temperatures. more specifically, jt = 1-5 means that the data are for the corresponding temperature of tref-30, tref-15, tref, tref+15, and tref+30, respectively. the second index, jp, runs from 13 to 59 and refers to the jpth reference pressure level (see taumol.f for the value of these pressure levels in mb). the third index, ig, goes from 1 to NG01=10, and tells us which g-interval the absorption coefficients are for.

Definition at line 1651 of file radlw_datatb.f.

◆ forref

real (kind=kind_phys), dimension(ng01,mfr01), public module_radlw_kgb01::forref

the array forref contains the coefficient of the water vapor foreign-continuum (including the energy term). the first index refers to reference temperature (296,260,224,260) and pressure (970,475,219,3 mbar) levels. The second index runs over the g-channel (1 to NG01=10).

Definition at line 1665 of file radlw_datatb.f.

◆ fracrefa

real (kind=kind_phys), dimension(ng01), public module_radlw_kgb01::fracrefa

planck fraction mapping level: p = 212.7250 mbar, t = 223.06 k

Definition at line 1668 of file radlw_datatb.f.

◆ fracrefb

real (kind=kind_phys), dimension(ng01), public module_radlw_kgb01::fracrefb

planck fraction mapping level: p = 212.7250 mbar, t = 223.06 k these planck fractions were calculated using lower atmosphere parameters.

Definition at line 1673 of file radlw_datatb.f.

◆ ka_mn2

real (kind=kind_phys), dimension(ng01,mmn01), public module_radlw_kgb01::ka_mn2

Definition at line 1675 of file radlw_datatb.f.

◆ kb_mn2

real (kind=kind_phys), dimension(ng01,mmn01), public module_radlw_kgb01::kb_mn2

Definition at line 1677 of file radlw_datatb.f.

◆ mfr01

integer, public module_radlw_kgb01::mfr01

mfr01=4

Definition at line 1624 of file radlw_datatb.f.

◆ mmn01

integer, public module_radlw_kgb01::mmn01

mmn01=19

Definition at line 1626 of file radlw_datatb.f.

◆ msa01

integer, public module_radlw_kgb01::msa01

msa01=65

Definition at line 1618 of file radlw_datatb.f.

◆ msb01

integer, public module_radlw_kgb01::msb01

msb01=235

Definition at line 1620 of file radlw_datatb.f.

◆ msf01

integer, public module_radlw_kgb01::msf01

msf01=10

Definition at line 1622 of file radlw_datatb.f.

◆ selfref

real (kind=kind_phys), dimension(ng01,msf01), public module_radlw_kgb01::selfref

the array selfref contains the coefficient of the water vapor self-continuum (including the energy term). the first index refers to temperature in 7.2 degree increments. for instance, jt = 1 refers to a temperature of 245.6, jt = 2 refers to 252.8, etc. the second index runs over the g-channel (1 to NG01=10).

Definition at line 1658 of file radlw_datatb.f.