This module sets up absorption coefficients for band 01: 10-350 cm-1 (low - h2o; high - h2o) More...
Variables | |
| integer, public | msa01 |
| msa01=65 | |
| integer, public | msb01 |
| msb01=235 | |
| integer, public | msf01 |
| msf01=10 | |
| integer, public | mfr01 |
| mfr01=4 | |
| integer, public | mmn01 |
| mmn01=19 | |
| real(kind=kind_phys), dimension(ng01, msa01), public | absa |
| the array absa(NG01,65) = ka(NG01,5,13) contains absorption coefs at the NG01=10 chosen g-values for a range of pressure levels>~100mb and temperatures. the first index in the array, jt, which runs from 1 to 5, corresponds to different temperatures. more specifically, jt = 1-5 means that the data are for the corresponding temperature of tref-30, tref-15, tref, tref+15, and tref+30, respectively. the second index, jp, runs from 1 to 13 and refers to the corresponding pressure level in pref (e.g. jp = 1 is for a pressure of 1053.63 mb). the third index, ig, goes from 1 to NG01=10, and tells us which g-interval the absorption coefficients are for. | |
| real(kind=kind_phys), dimension(ng01, msb01), public | absb |
| the array absb(NG01,235) = kb(NG01,5,13:59) contains absorption coefs at the NG01=10 chosen g-values for a range of pressure levels < ~100mb and temperatures. the first index in the array, jt, which runs from 1 to 5, corresponds to different temperatures. more specifically, jt = 1-5 means that the data are for the corresponding temperature of tref-30, tref-15, tref, tref+15, and tref+30, respectively. the second index, jp, runs from 13 to 59 and refers to the jpth reference pressure level (see taumol.f for the value of these pressure levels in mb). the third index, ig, goes from 1 to NG01=10, and tells us which g-interval the absorption coefficients are for. | |
| real(kind=kind_phys), dimension(ng01, msf01), public | selfref |
| the array selfref contains the coefficient of the water vapor self-continuum (including the energy term). the first index refers to temperature in 7.2 degree increments. for instance, jt = 1 refers to a temperature of 245.6, jt = 2 refers to 252.8, etc. the second index runs over the g-channel (1 to NG01=10). | |
| real(kind=kind_phys), dimension(ng01, mfr01), public | forref |
| the array forref contains the coefficient of the water vapor foreign-continuum (including the energy term). the first index refers to reference temperature (296,260,224,260) and pressure (970,475,219,3 mbar) levels. The second index runs over the g-channel (1 to NG01=10). | |
| real(kind=kind_phys), dimension(ng01), public | fracrefa |
| planck fraction mapping level: p = 212.7250 mbar, t = 223.06 k | |
| real(kind=kind_phys), dimension(ng01), public | fracrefb |
| planck fraction mapping level: p = 212.7250 mbar, t = 223.06 k these planck fractions were calculated using lower atmosphere parameters. | |
| real(kind=kind_phys), dimension(ng01, mmn01), public | ka_mn2 |
| real(kind=kind_phys), dimension(ng01, mmn01), public | kb_mn2 |
This module sets up absorption coefficients for band 01: 10-350 cm-1 (low - h2o; high - h2o)
| real (kind=kind_phys), dimension(ng01,msa01), public module_radlw_kgb01::absa |
the array absa(NG01,65) = ka(NG01,5,13) contains absorption coefs at the NG01=10 chosen g-values for a range of pressure levels>~100mb and temperatures. the first index in the array, jt, which runs from 1 to 5, corresponds to different temperatures. more specifically, jt = 1-5 means that the data are for the corresponding temperature of tref-30, tref-15, tref, tref+15, and tref+30, respectively. the second index, jp, runs from 1 to 13 and refers to the corresponding pressure level in pref (e.g. jp = 1 is for a pressure of 1053.63 mb). the third index, ig, goes from 1 to NG01=10, and tells us which g-interval the absorption coefficients are for.
Definition at line 1639 of file radlw_datatb.f.
| real (kind=kind_phys), dimension(ng01,msb01), public module_radlw_kgb01::absb |
the array absb(NG01,235) = kb(NG01,5,13:59) contains absorption coefs at the NG01=10 chosen g-values for a range of pressure levels < ~100mb and temperatures. the first index in the array, jt, which runs from 1 to 5, corresponds to different temperatures. more specifically, jt = 1-5 means that the data are for the corresponding temperature of tref-30, tref-15, tref, tref+15, and tref+30, respectively. the second index, jp, runs from 13 to 59 and refers to the jpth reference pressure level (see taumol.f for the value of these pressure levels in mb). the third index, ig, goes from 1 to NG01=10, and tells us which g-interval the absorption coefficients are for.
Definition at line 1651 of file radlw_datatb.f.
| real (kind=kind_phys), dimension(ng01,mfr01), public module_radlw_kgb01::forref |
the array forref contains the coefficient of the water vapor foreign-continuum (including the energy term). the first index refers to reference temperature (296,260,224,260) and pressure (970,475,219,3 mbar) levels. The second index runs over the g-channel (1 to NG01=10).
Definition at line 1665 of file radlw_datatb.f.
| real (kind=kind_phys), dimension(ng01), public module_radlw_kgb01::fracrefa |
planck fraction mapping level: p = 212.7250 mbar, t = 223.06 k
Definition at line 1668 of file radlw_datatb.f.
| real (kind=kind_phys), dimension(ng01), public module_radlw_kgb01::fracrefb |
planck fraction mapping level: p = 212.7250 mbar, t = 223.06 k these planck fractions were calculated using lower atmosphere parameters.
Definition at line 1673 of file radlw_datatb.f.
| real (kind=kind_phys), dimension(ng01,mmn01), public module_radlw_kgb01::ka_mn2 |
Definition at line 1675 of file radlw_datatb.f.
| real (kind=kind_phys), dimension(ng01,mmn01), public module_radlw_kgb01::kb_mn2 |
Definition at line 1677 of file radlw_datatb.f.
| integer, public module_radlw_kgb01::mfr01 |
mfr01=4
Definition at line 1624 of file radlw_datatb.f.
| integer, public module_radlw_kgb01::mmn01 |
mmn01=19
Definition at line 1626 of file radlw_datatb.f.
| integer, public module_radlw_kgb01::msa01 |
msa01=65
Definition at line 1618 of file radlw_datatb.f.
| integer, public module_radlw_kgb01::msb01 |
msb01=235
Definition at line 1620 of file radlw_datatb.f.
| integer, public module_radlw_kgb01::msf01 |
msf01=10
Definition at line 1622 of file radlw_datatb.f.
| real (kind=kind_phys), dimension(ng01,msf01), public module_radlw_kgb01::selfref |
the array selfref contains the coefficient of the water vapor self-continuum (including the energy term). the first index refers to temperature in 7.2 degree increments. for instance, jt = 1 refers to a temperature of 245.6, jt = 2 refers to 252.8, etc. the second index runs over the g-channel (1 to NG01=10).
Definition at line 1658 of file radlw_datatb.f.