← Back to Documentation Home
CCPP SciDoc v8.0.0  v8.0.0
Common Community Physics Package Developed at DTC
 
Loading...
Searching...
No Matches
module_radlw_kgb14 Module Reference

This module sets up absorption coefficients for band 14: 2250-2380 cm-1 (low - co2; high - co2) More...

Variables

integer, public msa14
 MSA14=65.
 
minor gas mapping level:
integer, public msb14
 MSB14=235.
 
integer, public msf14
 MSF14=10.
 
integer, public mfr14
 MFR14=4.
 
real(kind=kind_phys), dimension(ng14, msa14), public absa
 the array absa(NG14,65) = ka(NG14,5,13) contains absorption coefs at the NG14=2 chosen g-values for a range of pressure levels>~100mb and temperatures. the first index in the array, jt, which runs from 1 to 5, corresponds to different temperatures. more specifically, jt = 1-5 means that the data are for the corresponding temperature of tref-30, tref-15, tref, tref+15, and tref+30, respectively. the second index, jp, runs from 1 to 13 and refers to the corresponding pressure level in pref (e.g. jp = 1 is for a pressure of 1053.63 mb). the third index, ig, goes from 1 to NG14=2, and tells us which g-interval the absorption coefficients are for.
 
real(kind=kind_phys), dimension(ng14, msb14), public absb
 the array absb(NG14,235) = kb(NG14,5,13:59) contains absorption coefs at the NG14=2 chosen g-values for a range of pressure levels< ~100mb and temperatures. the first index in the array, jt, which runs from 1 to 5, corresponds to different temperatures. more specifically, jt = 1-5 means that the data are for the corresponding temperature of tref-30, tref-15, tref, tref+15, and tref+30, respectively. the second index, jp, runs from 13 to 59 and refers to the jpth reference pressure level (see taumol.f for the value of these pressure levels in mb). the third index, ig, goes from 1 to NG14=2, and tells us which g-interval the absorption coefficients are for.
 
real(kind=kind_phys), dimension(ng14, msf14), public selfref
 the array selfref contains the coefficient of the water vapor self-continuum (including the energy term). the first index refers to temperature in 7.2 degree increments. for instance, jt = 1 refers to a temperature of 245.6, jt = 2 refers to 252.8, etc. the second index runs over the g-channel (1 to NG14=2).
 
real(kind=kind_phys), dimension(ng14, mfr14), public forref
 the array forref contains the coefficient of the water vapor foreign-continuum (including the energy term). the first index refers to reference temperature (296,260,224,260) and pressure (970,475,219,3 mbar) levels. the second index runs over the g-channel (1 to NG14=2).
 
real(kind=kind_phys), dimension(ng14), public fracrefa
 planck fraction mapping level : p = 142.5940 mb, t = 215.70 k
 
real(kind=kind_phys), dimension(ng14), public fracrefb
 planck fraction mapping level : p = 4.758820mb, t = 250.85 k
 

Detailed Description

This module sets up absorption coefficients for band 14: 2250-2380 cm-1 (low - co2; high - co2)

Variable Documentation

◆ absa

real (kind=kind_phys), dimension(ng14,msa14), public module_radlw_kgb14::absa

the array absa(NG14,65) = ka(NG14,5,13) contains absorption coefs at the NG14=2 chosen g-values for a range of pressure levels>~100mb and temperatures. the first index in the array, jt, which runs from 1 to 5, corresponds to different temperatures. more specifically, jt = 1-5 means that the data are for the corresponding temperature of tref-30, tref-15, tref, tref+15, and tref+30, respectively. the second index, jp, runs from 1 to 13 and refers to the corresponding pressure level in pref (e.g. jp = 1 is for a pressure of 1053.63 mb). the third index, ig, goes from 1 to NG14=2, and tells us which g-interval the absorption coefficients are for.

Definition at line 31412 of file radlw_datatb.f.

◆ absb

real (kind=kind_phys), dimension(ng14,msb14), public module_radlw_kgb14::absb

the array absb(NG14,235) = kb(NG14,5,13:59) contains absorption coefs at the NG14=2 chosen g-values for a range of pressure levels< ~100mb and temperatures. the first index in the array, jt, which runs from 1 to 5, corresponds to different temperatures. more specifically, jt = 1-5 means that the data are for the corresponding temperature of tref-30, tref-15, tref, tref+15, and tref+30, respectively. the second index, jp, runs from 13 to 59 and refers to the jpth reference pressure level (see taumol.f for the value of these pressure levels in mb). the third index, ig, goes from 1 to NG14=2, and tells us which g-interval the absorption coefficients are for.

Definition at line 31424 of file radlw_datatb.f.

◆ forref

real (kind=kind_phys), dimension(ng14,mfr14), public module_radlw_kgb14::forref

the array forref contains the coefficient of the water vapor foreign-continuum (including the energy term). the first index refers to reference temperature (296,260,224,260) and pressure (970,475,219,3 mbar) levels. the second index runs over the g-channel (1 to NG14=2).

Definition at line 31438 of file radlw_datatb.f.

◆ fracrefa

real (kind=kind_phys), dimension(ng14), public module_radlw_kgb14::fracrefa

planck fraction mapping level : p = 142.5940 mb, t = 215.70 k

Definition at line 31441 of file radlw_datatb.f.

◆ fracrefb

real (kind=kind_phys), dimension(ng14), public module_radlw_kgb14::fracrefb

planck fraction mapping level : p = 4.758820mb, t = 250.85 k

Definition at line 31444 of file radlw_datatb.f.

◆ mfr14

integer, public module_radlw_kgb14::mfr14

MFR14=4.

Definition at line 31398 of file radlw_datatb.f.

◆ msa14

integer, public module_radlw_kgb14::msa14

MSA14=65.

Definition at line 31392 of file radlw_datatb.f.

◆ msb14

integer, public module_radlw_kgb14::msb14

MSB14=235.

Definition at line 31394 of file radlw_datatb.f.

◆ msf14

integer, public module_radlw_kgb14::msf14

MSF14=10.

Definition at line 31396 of file radlw_datatb.f.

◆ selfref

real (kind=kind_phys), dimension(ng14,msf14), public module_radlw_kgb14::selfref

the array selfref contains the coefficient of the water vapor self-continuum (including the energy term). the first index refers to temperature in 7.2 degree increments. for instance, jt = 1 refers to a temperature of 245.6, jt = 2 refers to 252.8, etc. the second index runs over the g-channel (1 to NG14=2).

Definition at line 31431 of file radlw_datatb.f.