This module sets up absorption coeffients for band 19: 4650-5150 cm-1 (low - h2o,co2; high - co2) More...
Variables | |
| integer, public | msa19 |
| MSA19=585. | |
Chou(1999) coefficients for cloud rain particles | |
| integer, public | msb19 |
| MSB19=235. | |
| integer, public | msf19 |
| MSF19=10. | |
| integer, public | mfr19 |
| MFR19=3. | |
| real(kind=kind_phys), dimension(msf19, ng19), public | selfref |
| the array selfref contains the coefficient of the water vapor self-continuum (including the energy term). the first index refers to temperature in 7.2 degree increments. for instance, jt = 1 refers to a temperature of 245.6, jt = 2 refers to 252.8, etc. the second index runs over the g-channel (1 to 8). | |
| real(kind=kind_phys), dimension(msa19, ng19), public | absa |
| the array absa(585,NG19) (ka(9,5,13,NG19)) contains absorption coefs at the 16 chosen g-values for a range of pressure levels> ~100mb, temperatures, and binary species parameters (see taumol.f for definition). the first index in the array, js, runs from 1 to 9, and corresponds to different values of the binary species parameter. for instance, js=1 refers to dry air, js = 2 corresponds to the paramter value 1/8, js = 3 corresponds to the parameter value 2/8, etc. the second index in the array, jt, which runs from 1 to 5, corresponds to different temperatures. more specifically, jt = 3 means that the data are for the reference temperature tref for this pressure level, jt = 2 refers to tref-15, jt = 1 is for tref-30, jt = 4 is for tref+15, and jt = 5 is for tref+30. the third index, jp, runs from 1 to 13 and refers to the jpth reference pressure level (see taumol.f for these levels in mb). the fourth index, ig, goes from 1 to 8, and indicates which g-interval the absorption coefficients are for. | |
| real(kind=kind_phys), dimension(msb19, ng19), public | absb |
| the array absb(235,8) (kb(5,13:59,8)) contains absorption coefs at the 16 chosen g-values for a range of pressure levels < ~100mb and temperatures. the first index in the array, jt, which runs from 1 to 5, corresponds to different temperatures. more specifically, jt = 3 means that the data are for the reference temperature tref for this pressure level, jt = 2 refers to the temperature tref-15, jt = 1 is for tref-30, jt = 4 is for tref+15, and jt = 5 is for tref+30. the second index, jp, runs from 13 to 59 and refers to the jpth reference pressure level (see taumol.f for the value of these pressure levels in mb). the third index, ig, goes from 1 to 8, and tells us which g-interval the absorption coefficients are for. | |
| real(kind=kind_phys), dimension(mfr19, ng19), public | forref |
| optical depth coefficients | |
| real(kind=kind_phys), parameter, public | rayl = 2.29e-09 |
| rayleigh extinction coefficient at \(v=4900cm^{-1}\) | |
This module sets up absorption coeffients for band 19: 4650-5150 cm-1 (low - h2o,co2; high - co2)
| real (kind=kind_phys), dimension(msa19,ng19), public module_radsw_kgb19::absa |
the array absa(585,NG19) (ka(9,5,13,NG19)) contains absorption coefs at the 16 chosen g-values for a range of pressure levels> ~100mb, temperatures, and binary species parameters (see taumol.f for definition). the first index in the array, js, runs from 1 to 9, and corresponds to different values of the binary species parameter. for instance, js=1 refers to dry air, js = 2 corresponds to the paramter value 1/8, js = 3 corresponds to the parameter value 2/8, etc. the second index in the array, jt, which runs from 1 to 5, corresponds to different temperatures. more specifically, jt = 3 means that the data are for the reference temperature tref for this pressure level, jt = 2 refers to tref-15, jt = 1 is for tref-30, jt = 4 is for tref+15, and jt = 5 is for tref+30. the third index, jp, runs from 1 to 13 and refers to the jpth reference pressure level (see taumol.f for these levels in mb). the fourth index, ig, goes from 1 to 8, and indicates which g-interval the absorption coefficients are for.
Definition at line 10201 of file radsw_datatb.f.
| real (kind=kind_phys), dimension(msb19,ng19), public module_radsw_kgb19::absb |
the array absb(235,8) (kb(5,13:59,8)) contains absorption coefs at the 16 chosen g-values for a range of pressure levels < ~100mb and temperatures. the first index in the array, jt, which runs from 1 to 5, corresponds to different temperatures. more specifically, jt = 3 means that the data are for the reference temperature tref for this pressure level, jt = 2 refers to the temperature tref-15, jt = 1 is for tref-30, jt = 4 is for tref+15, and jt = 5 is for tref+30. the second index, jp, runs from 13 to 59 and refers to the jpth reference pressure level (see taumol.f for the value of these pressure levels in mb). the third index, ig, goes from 1 to 8, and tells us which g-interval the absorption coefficients are for.
Definition at line 10214 of file radsw_datatb.f.
| real (kind=kind_phys), dimension(mfr19,ng19), public module_radsw_kgb19::forref |
optical depth coefficients
Definition at line 10216 of file radsw_datatb.f.
| integer, public module_radsw_kgb19::mfr19 |
MFR19=3.
Definition at line 10176 of file radsw_datatb.f.
| integer, public module_radsw_kgb19::msa19 |
MSA19=585.
Definition at line 10170 of file radsw_datatb.f.
| integer, public module_radsw_kgb19::msb19 |
MSB19=235.
Definition at line 10172 of file radsw_datatb.f.
| integer, public module_radsw_kgb19::msf19 |
MSF19=10.
Definition at line 10174 of file radsw_datatb.f.
| real (kind=kind_phys), parameter, public module_radsw_kgb19::rayl = 2.29e-09 |
rayleigh extinction coefficient at \(v=4900cm^{-1}\)
Definition at line 10219 of file radsw_datatb.f.
| real (kind=kind_phys), dimension(msf19,ng19), public module_radsw_kgb19::selfref |
the array selfref contains the coefficient of the water vapor self-continuum (including the energy term). the first index refers to temperature in 7.2 degree increments. for instance, jt = 1 refers to a temperature of 245.6, jt = 2 refers to 252.8, etc. the second index runs over the g-channel (1 to 8).
Definition at line 10184 of file radsw_datatb.f.