Description

Calculate the time constant TCRH (s) for an RS-80 radiosonde relative humidity sensor. The time constant is a function of pressure. The pressure pt (mb) is interpolated from a pressure series at time t. For a tropical atmosphere.

Formula

TCRH=18.30.02921pt+3.31105p2t1.4108p3t

Source

From Hal cole, via Editsonde.


Edit me
Tags: algorithm qc