Description

Calculate the time constant \(TC_{RH}\) (s) for an RS-80 radiosonde relative humidity sensor. The time constant is a function of pressure. The pressure \(p_t\) (mb) is interpolated from a pressure series at time \(t\). For a tropical atmosphere.

Formula

\[TC_{RH} = 18.3 -0.02921p_t + 3.31*10^{-5}p_t^{2} - 1.4*10^{-8}p_t^{3}\]

Source

From Hal cole, via Editsonde.


Edit me